Namespace for interfaces and classes of the PLC Domain More...
Classes | |
class | PlcDomainProxy |
Enumerations | |
enum class | PlcStartKind : uint8 { None = 0 , Cold = 1 , Warm = 2 , Hot = 3 , RestoreWarm = 4 } |
enum class | PlcState : uint32 { None = 0 , Ready = 1 , Stop = 2 , Running = 3 , Halt = 4 , StateMask = 0x3F , FlagsMask = ~StateMask , Warning = (1 << 6) , Error = (1 << 7) , SuspendedBySwitch = (1 << 8) , Suspended = (1 << 8) , FatalError = (1 << 9) , SuspendedBySystemWatchdog = (1 << 10) , Blocked = (1 << 10) , Loading = (1 << 12) , Starting = (1 << 13) , Stopping = (1 << 14) , Resetting = (1 << 15) , Changing = (1 << 16) , Hot = (1 << 17) , Forcing = (1 << 18) , Debugging = (1 << 19) , Warm = (1 << 20) , StartingDelayed = (1 << 21) , DcgFailed = (1 << 29) , DcgNotPossible = (1 << 30) , DcgRealTimeViolation = (1U << 31) , ClearMask = StateMask | Hot | Warm | Changing | Forcing | Debugging , RemainingMask = StateMask | Hot | Warm | Forcing | Debugging | Warning | Error | FatalError } |
Functions | |
ARP_CXX_SYMBOL_EXPORT std::ostream & | operator<< (std::ostream &os, PlcStartKind value) |
ARP_CXX_SYMBOL_EXPORT std::istream & | operator>> (std::istream &is, PlcStartKind &value) |
ARP_CXX_SYMBOL_EXPORT std::ostream & | operator<< (std::ostream &os, PlcState value) |
ARP_CXX_SYMBOL_EXPORT std::istream & | operator>> (std::istream &is, PlcState &value) |
constexpr PlcState | operator& (PlcState lhs, PlcState rhs) |
constexpr PlcState | operator| (PlcState lhs, PlcState rhs) |
PlcState & | operator&= (PlcState &lhs, PlcState rhs) |
PlcState & | operator|= (PlcState &lhs, PlcState rhs) |
PlcState | operator~ (PlcState arg) |
Namespace for interfaces and classes of the PLC Domain
|
strong |
Enumerator | |
---|---|
None | Not specified. |
Ready | The firmware is setup, and the PLC is ready. |
Stop | The PLC is loaded and setup but not started yet. |
Running | The PLC is started. |
Halt | The PLC is halted for debug purpose. |
StateMask | Use this entry to de-mask the raw PLC state value. |
FlagsMask | Use this entry to de-mask the flags portion of this PLC state. |
Warning | An unspecified warning occurs. |
Error | An unspecified error or exception occurs, and the PLC is in state error. |
SuspendedBySwitch | Deprecated since 2022.0! Please use <cref name="Suspended"> instead. This error bit is set, if it could not be started because the PLC is suspended by the hardware switch (STOP-switch). |
Suspended | This error bit is set, if the PLC could not be started because it was prevented by a component. |
FatalError | An unspecified fatal error or exception occurs, and the PLC is in state error. |
SuspendedBySystemWatchdog | Deprecated since 2022.0! Please use <cref name="Blocked"> instead. This error bit is set, if the PLC could not be loaded because it is blocked by the system watchdog. |
Blocked | This error bit is set, if the PLC could not be loaded because it was prevented by a component. |
Loading | The PLC is loading the Plc components. |
Starting | The PLC is starting the Plc components. |
Stopping | The PLC is stopping the Plc components. |
Resetting | The PLC is resetting the Plc components. |
Changing | The PLC is changing a configuration, this implies, that the state Running is set. |
Hot | The PLC is stopped in hot state, that is all data still remains. |
Forcing | The PLC is in force mode. One or more variables are forced by the GDS. |
Debugging | The PLC is in debug mode. One or more breakpoints are set. |
Warm | The PLC is stopped in warm state, that is the retain data has been restored. |
StartingDelayed | The PLC is about to start, but due to component conditions the PLC start has to be delayed. |
DcgFailed | This error bit is set, if the PLC tried to perform a change operation, but an error occurred. This bit is usually combined with the state Running. |
DcgNotPossible | This error bit is set, if the PLC tries to perform a change operation, but it is not possible. This bit is usually combined with the state Running. |
DcgRealTimeViolation | This error bit is set, if the PLC tries to perform a change operation, but it is not possible in real time. This bit is usually combined with the state Running. |
ClearMask | This mask defines all states which should be cleared before any PLC operation. It is a combination of all bits which should remain. ARP_DEPRECATED("Use RemainingMask instead. The name of this entry is not self-explanatory.") |
RemainingMask | This mask defines all states which should not be cleared before any PLC operation. All other flags are reset. It is a combination of all bits which should remain. |